版权所有 苏ICP备14044490号-1 网站建设:中企动力 南京

Product display

Dyj-k anti-overflow controller

basic information
heat
没有此类产品
I want to inquire
Product introduction

Using range

Dyj-k anti-overflow controller is designed for top petrochemical product loading and unloading. The system detects the liquid level signal through the DOP explosion-proof sensor. When the liquid level exceeds the set alarm position, the equipment will sound and light alarm, and at the same time output the relay switch volume signal for oil payment and other loading and unloading system control.
 
Especially suitable for liquid petrochemical products with frequent turnover, such as inflammable and explosive, etc., such as:
 
1. Fuel oil loading system (including railway tank car and road tank car);
 
2. Sealed loading of liquid benzene and hydrocarbons;
 
3. Filling system of other chemical products;

 

System composition and functions

Dyj-k anti-overflow controller is mainly composed of main controller and DOP anti-explosion sensor.

江苏德大石化科技有限公司1. Main controller

A. Detect the DOP explosion-proof liquid level sensor signal;
 
B. Drive the acoustooptic alarm to issue the acoustooptic alarm signal;
 
C. Output relay switching signal to loading/unloading system such as oil payment;

 

江苏德大石化科技有限公司2.DOP explosion-proof sensor

The DOP explosion-proof level sensor USES optical principle to detect the liquid level in the loading and unloading tank truck
 
Situation. It is bundled with crane tube mounting to the main controller
 
Provide liquid level signal, realize linkage control with loading and unloading system.

A. Optical principle, integral safety design;

江苏德大石化科技有限公司

B. Convenient installation and adjustment, and adjustable alarm height through stainless steel clip positioning device;
 
C. Wide input voltage range, full digital circuit design, strong anti-interference capability;
 
D. The standard distribution cable is 7 meters long (the cable length can be customized).
 
E. Explosion-proof tuning fork liquid level sensor is optional
Technical Parameters
Explosion-proof certificate
1. The level of explosion-proof: Ex dia Ⅱ T6 Gb B
 
2. Working voltage: DC24V plus or minus 10%/AC220V plus or minus 10%(DC24V is non-polar)
 
3. Maximum working current: <50mA
 
5. Protection level: IP65
 
6. Response time: <1s
 
7. Working temperature: - 40 ℃ ~ + 60 ℃
 
8. Output signal: 1 relay output, normally on and off
 
9. Interface capacity: 10A,30VDC; 10. A, 250 vac

 

Field installation diagram of dyj-k anti-overflow controller

 

 

Appendix 5 installation dimensions of dyj-k anti-overflow controller

 

江苏德大石化科技有限公司